1
0
mirror of https://github.com/Utyff/Zintercom.git synced 2026-01-12 09:17:41 +03:00

Update README.md

This commit is contained in:
John Doe
2021-08-07 00:05:37 +08:00
committed by GitHub
parent 5de49cbeae
commit 7994aead0c

View File

@@ -7,21 +7,21 @@ Follow this article https://zigdevwiki.github.io/Begin/IAR_install/
This device is designed to control the matrix intercom using Zigbee.
Using zigbee2mqtt you can:
1. Receive notification when the intercom rings. (also support **direct bind**)
1. Receive a notification when the intercom rings. (also support **direct bind**)
2. Mute the sound on the intercom handset.
3. Automatically or manually open the door or hang up when the intercom rings.
There are 4 work modes:
1. `Never` - ordinary work mode, use handset to control
2. `Once` - one time open door when intercom rings
1. `Never` - ordinary work mode, use a handset to control
2. `Once` - one-time open door when intercom rings
3. `Always` - open door when intercom rings
4. `Drop` - hangs up all intercom rings, right after start
4. `Drop` - hangs up all intercom rings, right after the start
You can change the operating mode uisng z2m or by short press the button. (< 1000ms)
You can change the operating mode using z2m or by short press the button. (< 1000ms)
After pressing the button, the LED will flash at 4 Hz.
The number of flashes indicates the current operating mode.
You can control sound mode using z2m or by long press the button. (1000ms < X < 5000ms)
You can control sound mode using z2m or by long-press the button. (1000ms < X < 5000ms)
After pressing the button, the LED will flash at 1.5 Hz.
One flash - OFF, two flashes - ON.
@@ -37,7 +37,7 @@ Just plug by swapping.
#### 2
The problem of cross-calls to other apartments:
it was revealed that the intercom circuit is closed through the reverse diode of the u2 transitor (thanks to @Alex_AW)
it was revealed that the intercom circuit is closed through the reverse diode of the u2 transistor (thanks to @Alex_AW)
to prevent it, you need to add a diode according to the diagram:
![](/images/fix_error_rings.png)
@@ -47,8 +47,8 @@ If you want to use the battery version without a handset, do not turn off the so
### How to join
Reset to FN by reboot device 5 times with interval less than 10 seconds.
Reset to FN by press and hold BTN for 5 seconds.
Reset to FN by reboot the device 5 times with intervals of less than 10 seconds.
Reset to FN by pressing and holding BTN for 5 seconds.
LED will flash during reset.
@@ -95,7 +95,7 @@ Install `E18-MS1-PCB` only!
Do not turn off `sound` because it turns U2 forever, which will drain the battery much faster.
Since the device is in sleep mode, it cannot receive commands.
But you have the ability to set the button mode or at the time of the call.
But you can set the button mode or at the time of the call.
If any commands are in the coordinator's queue, they will be executed after a button is pressed or a call is received.
@@ -104,7 +104,7 @@ If any commands are in the coordinator's queue, they will be executed after a bu
##### The mode set by the Zigbee command `overwrites` the mode set by the button.
### Binding
The device supports direct binding of an incoming call to the onOff cluster.
The device supports the direct binding of an incoming call to the onOff cluster.
For example, you can turn on the light while a call comes to the intercom, for notification in mute mode.